1成果简介
脊柱运动学的连续监测对姿态矫正与康复至关重要,然而传统的影像学与基于摄像机的动作捕捉受限于"单次快照"式信息且依赖专业医疗设备。可穿戴传感器阵列虽能通过追踪关键肌肉形变实现脊柱监测,但阵列内通道间差异往往会降低形变映射的精度。因此,开发通道一致性强、可规模化制备的柔性传感阵列具有重要意义。本文,深圳技术大学 史济东 副教授团队在《Small》期刊发表名为"Propylene Glycol-Assisted Printing of Graphene Piezoresistive Sensor Array for Analytical Motion Tracking and Spinal Kinetics Monitoring"的论文,研究提出了一种"印刷-转移"法制备石墨烯压阻传感器阵列。该阵列以相纸为中间基底、以丙二醇(PG)为墨水工程添加剂,克服了石墨烯分散液与柔性 PDMS 基底难以兼容均一成膜的问题。
此外,PG 不仅在石墨烯分散液中改善印刷适性,还在石墨烯-相纸界面形成过渡层,从而实现了从相纸向 PDMS 基底的高成品率薄膜转移。经测试,该 8 通道阵列的基线电阻通道间差异仅为 4.12%,实现了极高的通道一致性;在脊柱动力学监测中,结合机器学习算法可区分 6 种躯干姿态,分类准确率达 95.4%。同时,该可穿戴阵列还可用于日常脊柱健康追踪,在疾病预防和康复监测中展现出应用前景。本研究提出了一种可规模化的"印刷-转移"石墨烯传感平台,该策略从根本上解决了阵列通道间一致性差的难题,并为日常脊柱健康监测与康复管理提供了新的技术思路。
2图文导读
图1、Design and preparation of the graphene-based piezoresistive sensor array. (a) Schematic illustration of a sensor array attached on a compression vest for spinal kinetics monitoring. (b) Schematic illustration of the sensor array structure. (c) Schematic illustration of the fabrication process of the sensor array. (d) Schematic illustration of PG-assisted delamination of graphene from the photo paper. (e) The photograph of graphene residues on photo paper after transfer process. Top: Direct transfer without PG. Bottom: PG-assisted transfer. (f) The photograph of the electromechanical sensor array withstanding bending (top) and stretching (bottom) deformation.
图2、Performance of the electromechanical sensor array. (a) Schematic illustration of graphene film's morphological evolution under tensile stretch. (b) The electromechanical response of a single sensor under 4 stretch-release cycles with a strain of 2%, 4%, 8% and 12%. (c) The electromechanical response of a single sensor under different stretching and releasing frequencies with a stain of 4%. (d) Durability test of a single sensor under 5000 stretch-release cycles. (e) The electromechanical response of a single sensor under stepwise augmentation and reduction of strains. The sensor used in (a–d) is based on a graphene film printed by 5 cycles. (f) The sheet resistance of the graphene film printed by 2–5 times. (g) The electromechanical behavior of the graphene film printed by 2–5 times. (h) The resistances of the 8 channels within a sensor array. (i) The electromechanical behavior of the 8 channels within a sensor array. (j) The comparison of electromechanical behavior between deposited graphene film and th e silver electrode.
图3、On-skin sensing of human biomechanical signals by a single sensor. (a) The diagram of wearable sensing of various human biomechanical signals. (b) The electrical response during neck bending with different angles. The bending angle is defined in the inset image. (c) The electrical response during finger bending with different angles. The bending angle is defined in the inset image. (d) Pulse recording at resting state and during exercise. (e) The electrical response during eyes blink motion. (f) The electrical recording upon phonation of the word “soft”. (g) The electrical recording upon phonation of the word “graphene”. (h) The electrical recording upon phonation of the word “stretch”.
图4、Application of the electromechanical sensor array for wireless analytical motion tracking. (a) The photograph of the sensor array integrated with a Bluetooth module. (b) Digitalization process of the multi-channel signals for wireless transmission. (c) The photograph for testing (top), multi-channel electrical recording (middle) and external resistance level-dependent signal amplitude (bottom) during knee flexion–extension exercise. (d) The photograph for testing (top), multi-channel electrical recording (middle) and external resistance level-dependent signal amplitude (bottom) during rowing exercise. (e) The photograph for testing (top), multi-channel electrical recording (middle) and external resistance level-dependent signal amplitude (bottom) during chest press exercise.
图5、Machine learning-assisted spinal kinetics monitoring by the sensor array. (a) Schematic illustration of a sensor array adhered on the back (left), as well as the typical signal patterns of the 8 channels during the 6 defined trunk postures (right), including slouched standing, head-down sitting, left-leaning sitting, right-leaning standing, left-leaning standing, right-leaning sitting (from top to bottom). (b) Schematic illustration of the machine learning-assisted trunk posture recognition process, including pre-processing of the recorded electrical signal, feature extraction using the 1D-CNN, as well as the data training and validation process. (c) Epoch-dependent training and validation accuracy curves, indicating fast convergence and stable learning behavior of the model. (d) Dimensionality-reduced feature-space distribution of different postures, revealing distinct cluster separation among motion classes. (e) Confusion matrix from 100 repeated validation runs of the trained model, yielding a classification accuracy of 95.4% in recognizing the 6 trunk postures, including slouched standing, head-down sitting, left-leaning sitting, right-leaning standing, left-leaning standing, right-leaning sitting (from top to bottom, and from left to right).
3小结
综上所述,我们通过一种优化的分步印刷与转印方法,开发了一种基于石墨烯的高性能压阻式传感器阵列。通过采用光面相纸作为中间沉积基板,并运用创新的PG辅助墨水工程技术,该传感器阵列不仅展现出卓越的单单元传感性能,还在薄膜电阻(CV = 4.12%)和机电行为方面实现了出色的通道间一致性,从而能够可靠地映射贴附后的皮肤变形。该传感器阵列可与蓝牙模块集成,用于无线记录健身锻炼中的机电特征,并能通过区分6种躯干姿势以95.4%的准确率监测脊柱动力学。值得注意的是,本研究建立了工艺赋能特性与日常脊柱动力学监测需求之间的直接联系。该传感器阵列将通道间偏差降至最低,且具备大面积可图案化特性,有助于以可靠且全面的方式追踪脊柱生物力学。其机械顺应性及服装级集成性确保了设备的长期耐用性。总体而言,这一新开发的传感器阵列为智能可穿戴脊柱监测提供了极具前景的平台,其广阔的应用潜力可延伸至生理监测、动作感知以及基于分析方法的人机交互领域。
文献: